Dual-branch extract fans
FN-100 - Dual-Branch Extract Fan
Single speed listed
View specifications ↗
Supplier product photograph. Original product markings are retained for this preview.
Ceiling extract fans
A ceiling-mounted extract fan with an automatic shutter that opens during operation and closes after shutdown to reduce reverse airflow.
Availability, configuration and pricing confirmed on enquiry.
SEE HOW IT WORKS
The front shutter opens for extraction and closes after shutdown to help limit reverse airflow.

The shutter covers the opening when closed.

After switching on, the catalogue describes an approximately 30-second self-check before automatic opening.

The opening is exposed for extraction. After switching off, the shutter closes automatically after a self-check.
Do not force the shutter open by hand. The catalogue does not specify the shutdown self-check duration.
PRODUCT DETAILS
The catalogue illustrates a ceiling-mounted extract fan connected by ductwork to an unobstructed outdoor outlet.

Three spring clips attach to the mounting bracket with screws.

Compress the spring clips for insertion and release them to retain the fan in the ceiling.
Room air enters below the ceiling, passes through the duct and exits outdoors.
The drawing marks a 150 mm outlet; the installation text describes an approximately 155 mm hose. Confirm hose and clamp compatibility and use the model-specific installation manual.
PRODUCT DETAILS
Supplier drawing values: face diameter 285 mm; central opening 128 mm; overall depth 166 mm; rear projection 129 mm; nominal outlet 150 mm; ceiling cut-out 255 mm.
Dimensions in millimetres. The cut-out annotation is translated into English. Confirm the latest drawing before installation.

Catalogue photograph showing the front shutter, body and mounting clip.
CATALOGUE DATA
| Configuration / model | Voltage (V) | Frequency (Hz) | Speed setting | Input power (W) | Airflow | Airflow unit | Pressure unit | Noise (dBA) |
|---|---|---|---|---|---|---|---|---|
| MY-150W2 | 220 | 50 | On | 28 | 210 | m3/h | Pa | 24 |
Scroll horizontally to compare all fields. Each row describes its own voltage and operating configuration.
Values and performance curves are supplied in the product catalogue. They are not independent BROSNGAN test results. Airflow and maximum static pressure are separate catalogue ratings, not a simultaneous duty point. Noise test conditions and measurement distance are not provided. Confirm the exact voltage, configuration, dimensions and applicable test reports before ordering.
COMPARE THE RANGE
LET'S FIND YOUR AIRFLOW